PL ENG DE SWE RU  
/\ \/

Accessories for mounting of sandwich panels

Standard roof panel flashings
Nr Image Scheme Name Symbol
1. no image no image Ridge, Crest flashing O-K
1a. no image no image Pent roof ridge
(open mono-slope roof)
O-KJ
1b. no image no image Pent roof ridge
mono-slope roof
(adjacent to the wall)
O-KS
2. no image no image Bottom ridge flashing O-PK
3. no image no image Peak profile masking O-G
4. no image no image Side flashing O-W
5. no image no image Side flashing (free trapeze) O-WWT
6. no image no image Drip flashing O-PN
7. no image no image Fascia flashing O-PP
8. no image no image Trapeze masking O-MT
9. no image no image Drainpipe mounting element

more...
O-PMR
We also produce other flashings on request.
Standard wall panel flashings
Nr Image Scheme Name Symbol
10. no image no image U-profile O-C
11. no image no image Flat flashing O-PL
12. no image no image Outside
corner flashing
O-KTZ
13. no image no image Inside
corner flashing
O-KTW
14. no image no image Wall starting sill, sill flashing O-OKP
14a. no image no image Wall drip O-OKS
15. no image no image Pannel connection masking
on horizontal mounting
(hidden joints, screws)
O-ML
16. no image no image Profiled corner
(hidden joints, screws)
O-N
Other flashing on demand.
Flashing dimensions
Standard and maximum length of flashings: 3000mm
Profile masking 1000mm (1 piece per panel)
Trapezez masking (4 pcs per panel + 1 piece on every roof slope
Drainpipe mounting element (amount depends on the mounting system - min. 2 pieces per panel)
Non-standard, other flashings - We can produce flashings according to customers design.
Farm screws, flashing screws

We offer special steel sheet screws, farm screws with underlay and sealant or without sealant for mounting of flashings.
flashing screws (farm screws)
no image flashing screws, "farm screws" - galvanised -
no image flashing screws, "farm screws" - galvanised and RAL painted RAL colors
Self drilling screws for metal constructions with metal washers/underlays and sealants
no image for thin-walled construcions (2-3mm)< /td> -
no image for thick-walled construcions (4-12mm)
(possible are also screws for thicker construcions - ask for availability)
-
no image galvanised and painted RAL colors
screws with metal washers/underlays and sealants for wooden constructions
no image screws for wooden constructions -
no image galvanised -
no image galvanised and painted with metal washer/underlays RAL colors
screws for concrete constructions
no image for concrete without dowel -
no image for concrete with dowel -
no image concrete drills -
drainpipe mounting
no image drainpipe mounting element - PMR more...
mounting calotes
no image calottes for roof panels RAL colors
masking caps
no image masking caps RAL colors
recommended amount of screws for EURO-therm panel mounting
Mounting info Amount (pcs)
Recommended screw amount typically 4 screws per 1m2
When mounting to a steel construction typically 2 pieces per purlin.
edge panels and drip - 4 screws per purlin.
Keeping the right purlin distances is very important.
Sealants and fillings
no image profile sealant

(used for the trapeze profile on the roof ridge)
width 1000mm
(in pieces
1/panel)
no image polyurethane sealants (PU)

(because of better panel fitting on locks it is unnecessary to use sealants between EURO-therm S and EURO-therm D panels)
various sizes
no image polyethylene sealants (PE)

(for steel constructions)
various sizes
Front mounting of drainpipes - use of drainpipe mounting element PMR
podkładka montażowa rynny

(click to enlarge)

podcinanie rdzenia

(click to enlarge)

umiejscowienie podkładki montażowej rynny

(click to enlarge)

schemat montażu rynny

(click to enlarge)

przykład montażu rynny

(click to enlarge)

Informations about flat flashing steel sheets
no image
width:1250mm
steel sheet thickness 0,5mm
standard length 2000mm
possible lengths any (also in coils)
type of steelgalvanised prepainted, inox
Standard galvanised and galvanised steel sheets - parameters
type of material galvanised, poliester painted steel sheets
steel sheet thickness 0,5 mm
galvanic layer thickness 225 g/m² - 275 g/m²
poliester coating layer 25 μm
decorative varhinsh 2V078
bottom varnish 1G410 - 7 μm
Possible steel thickness 0,45mm - 0,6mm
Protective film

Sandwich panel claddings (prepainted steel sheet covers and flashings) are covered with a layer of protective film. The protective film must be removed from the panels before 1 month after recieving the plates. For longer storage panels should be protected from sun exposure, extremal temperatures and other atmospheric conditions. A good practice is to place panel packs with a small decrease, causing rainwater run off.
Cutting of sandwich panels and flashings.

You should use proper tools for cutting sandwich panels, that do not overheat the steel surface. Excessive heat during metal cutting (eg. An angle grinder with discs) damages the galvanic coating of steel sheets and can be a cause of corrosion. Great heat can also excessively damage the core, insulation. To cut sandwich panels use circular saws for metal cutting, special sandwich panel - saws or other proper equipment. When cutting panels remove excess metal filings that can cause corrosion, and prevent sparks and filings from falling onto other panels.
Standard ABO colors

RAL 9010

RAL 9002

RAL 9006

RAL 3011

RAL 8017

RAL 7024

The colors depicted on the website are for guidance only and can be different from real color coatings on panels.
Availability, production possibilities and pricing of certain colors are determined individually.
Other color examples

RAL 1002

RAL 1015

RAL 1021

RAL 5010

RAL 6029

RAL 7035

RAL 9007

The colors depicted on the website are for guidance only and can be different from real color coatings on panels.
Availability, production possibilities and pricing of certain colors are determined individually.
The informations and materials given above

(on this website)

are for informational purposes only. Informations contained therein are not legally binding and do not constitute an offer within the meaning of Article 66 § 1 of the polish civil code do not constitute assurance, in particular within the meaning of art. 556 of the polish civil code. Description and confirmation of availability of goods takes place only during sale according to specifications provided by the Sandwich Panel Factory ABO (Fabryka Płyt Warstwowych ABO Boguslaw Bugała) in the form of a contract, purchase order or order confirmation.
back print
address:
Fabryka Płyt Warstwowych ABO Bogusław Bugała
factory: Mchowo 100, 06-300 Przasnysz
invoicing: Mchowo 1, 06-300 Przasnysz
województwo mazowieckie, POLAND
GPS: N 53°04'15.09" | E 20°51'02.88"
contact:
tel: (+48) 29-751-34-01
fax: (+48) 29-751-34-03
e-mail:
Bank: Bank Pekao S.A. / Bank account No.:
EURO: (IBAN): PL59 1240 1617 1978 0010 3691 5883
PLN: (IBAN): PL39 1240 1617 1111 0010 3691 5652
SWIFT: PKOPPLPW

Last update:  13.10.2017 - Copyright © 2016 Fabryka Płyt Warstwowych ABO
webmaster 

Powered by PHP Poprawny HTML 4.01 Transitional Poprawny CSS