EURO-therm St sandwich panels with expanded polystyrene core are the most economical solution for roofs, outside and inside walls. The right profilation of panels provides tightness and stiffness, the polystyrene core placement system on the panel connection makes using of additional sealants unnecessary, which greatly accelerates the installation of the panels and makes it easier. The core enclosed in galvanised and poliester coated steel sheet cladding provides good insulation. EURO-therm St wall panels are used as an economical, easy to install and safe cladding for walls and roofs of halls, warehouses, large stores, garages, containers, cold rooms, pavilions, agricultural buildings, such as barns, piggeries, chicken coops, sheds, storage of vegetables and fruits.
choose ->

(click on image)
no image no image
panel type EPS wall panels EPS roof panels
marking EURO-therm S-St EURO-therm D-St
width 1175 mm (effective, covering) 1000 mm (effective, covering)
length up to 14 m (other lengths possible) up to 14 m (other lengths possible)
panel cladding (covers) galvanised and prepainted steel sheet galvanised and prepainted steel sheet
core, insulation expanded polystyrene (EPS) expanded polystyrene (EPS)
standard thickness 55 mm - 250 mm 50 mm - 250 mm
thickness (mm) 100 120 150 200 250 100 120 150 200 250
U [W/m2K] * 0,37 0,32 0,25 0,19 0,15 0,37 0,32 0,25 0,19 0,15
weight (kg/m2) * 11,71 12,11 12,71 13,71 14,10 11,94 12,34 12,94 13,94 14,15
reaction to fire - E (for thickness: 50mm-250mm)
fire spreading
(external fire exposure)
- Broof(t1) (for thickness: 100mm-250mm)
more... more...
* Estimated or calculative data.
** Fire resistance classifications depend on the spans spacing of the construction and its resistance to fire.

Detailed informations

Standard dimensions of roof sandwich panels
effective width
(covering width)
1000 mm
modular width
(with overlapping trapeze and lock)
1100 mm
standard minimum length 2,7 m
possible minimum length od 0,5 m
recommended maximum length
in bright colors
up to 12 m
recommended maximum length
in dark colors
up to 10 m
possible maximum length
(on special order)
up to 16 m (restrictions because of thickness, color, guarantee limitation)
standard thickness (mm) 50, 60, 80, 100, 120, 150, 200, 250
possible thickness (mm) 40 - 300
Production of panels with different thickness and lengths on special orders is possible.
Standard dimensions of wall sandwich panels
effective width
(covering width)
1175 mm*
modular width (with locks) 1194 mm
standard minimum length 2,7 m
possible minimum length from 0,5 m
recommended maximum length
for outside walls in bright colors
up to 6 m
recommended maximum length
for outside walls in dark colors
up to 4 m
recommended maximum length
for partition walls - inside walls
up to 12 m (on longer panels there is a higher risk of damaging during mounting)
maximum length
for partition walls - inside walls
up to 16 m (limitations because of thickness, guarantee restriction)
standard thickness (mm) 55, 60, 80, 100, 120, 150, 200, 250
possible thickness (mm) 40 - 300
Production of panels with different thickness and lengths on special orders is possible.
* for an extra charge it is possible to produce panels with effective widht: 1000mm.
Panel length and temperature expansion

We do not recommend the use of very long sandwich panels mainly on the walls, but in some cases also roofs due to sunlight (temperature expansion of metal), as well as the difficulties associated with the unloading and assembling long panels. Wall panels should be installed single-spanned. Using too long elements may result in deterioration of aesthetic or damage panels. We are not responsible for damages resulting from the use of too long sandwich panel pieces or incorrect assembly. We do not provide guarantee for panels ordered against our recommendations concerning colors and lengths.
Top cladding profilation of roof panels
T35

trapeze corrugation T35
(standard profilation)

no image

(click to enlarge)

no image

(click to enlarge)

no image

(click to enlarge)

Bottom cladding profilation of roof panels
L

lined profile
(standard profilation)

no image

(click to enlarge)

no image

(click to enlarge)

no image

(click to enlarge)

G

flat
(no profilation)

no image

(click to enlarge)

no image

(click to enlarge)

Standard profilation of roof panels is T35/L, on special order other profilations of bottom side are possible. For more informations please contact us.
Outside cladding profilation of wall sandwich panels
L

linear
(standard profilation)

no image

(click to enlarge)

no image

(click to enlarge)

no image

(click to enlarge)

R

grooving

no image

(click to enlarge)

no image

(click to enlarge)

no image

(click to enlarge)

G

flat, plain
(no profilation)

no image

(click to enlarge)

no image

(click to enlarge)

Inside cladding profilation of wall sandwich panels
R

grooving
(standard profilation)

no image

(click to enlarge)

no image

(click to enlarge)

no image

(click to enlarge)

G

flat, plain
(no profilation)

no image

(click to enlarge)

no image

(click to enlarge)

Standard profilation of wall panels is L/R, on special orders other profilation combinations are possible, for additional informations please contact us.
Connection scheme of roof sandwich panels with EPS core
section drawing of roof panel connection (schemat) connection of roof sandwich panels
no image

(click to enlarge)

no image

(click to enlarge)

It is possible to connect EPS panels and mineral wool panels of the same type.
Connection scheme of wall sandwich panels with EPS core
mounting of wall sandwich panels connection lock scheme
no image

(click to enlarge)

no image

(click to enlarge)

It is possible to connect EPS panels and mineral wool panels of the same type.
Parameters of EURO-therm St sandwich panels with expanded polystyrene (EPS)
core, insulation thickness heat
transfer
coefficient U*
fire resistance
(depends on fire resistance and spans of the construction)
weight kg/m2* acoustic
isolation*
mm (W/m2K) dach ściana dach ściana Rw(dB)
40 0,65 - - 10,74 10,51 24
50 0,62 reakcja na ogień: E - 10,94 10,71
60 0,59 reakcja na ogień: E - 11,14 10,91
80 0,46 reakcja na ogień: E - 11,54 11,31
100 0,37 Broof(t1), reakcja na ogień: E - 11,94 11,71
120 0,32 Broof(t1), reakcja na ogień: E - 12,34 12,11
150 0,25 Broof(t1), reakcja na ogień: E - 12,94 12,71
200 0,19 Broof(t1), E - 13,94 13,71
250 0,15 Broof(t1), E - 14,15 14,10
Fire resistance classifications depend on the spans spacing od the construction and its resistance to fire.
* Estimated or calculative data.
Panel amount in packs
Sandwich panels are stacked in packs wrapped with stretch foil. Roof panels are placed alternately (trapezes facing eachother).
Final amount of sandwich panels in each pack can differ slightly from the amounts indicated in the table.
thickness (core, insulation thickness) Amount of panels per pack
wall panels
EURO-therm S
roof panels
EURO-therm D
50 24 18
55 22 16
60 20 16
80 15 12
100 10 - 12 10 - 11
120 10 8 - 9
150 7 - 8 (usually 7 + 8) 7 - 8 (usually 7 + 7)
200 5 - 6 4 - 6 (usually 4 + 6)
250 4 - 5 4
height of packs: approximately 1200mm; width of packs: approximately 1200mm (packs lie on EPS supports - approx. 100mm)
Amount of panels in packs depends on the total panel amount per order. Packs with different amount of panels are possible. For more informations, to specify details of packing please contact us.
Loading and Transport

Standard loading and unloading is done with a forklift (fitted to the dimensions and weight of the wares)
Loading space dimensions must consider the height of the packs with EPS supports, and space for the belts and a securing bar.
Required standard width of the vehicle loading space: 2,4m
The vehicle should provide free acess from both sides of the loading space on its full length, alowing loading and unloading of the wares.
More information about the transport can be found in the Informations section -> download.

Loading times in our Factory are from monday to friday 7:00 - 15:00.
Please contact us before pickup to set up the date and details of loading.
We kindly ask you for an earlier arrival of the truck, so the loading can be finished before 15:00.


For additional informations please contact our office.
Characteristics of the expanded polystyrene core
insulation, core expanded polystyrene
density EPS 70
fire resistance - reaction to fire self-extinguishing
Production of panels with different mineral wool type is possible. (graphite EPS, EPS 80, EPS 100).
Standard galvanised and galvanised steel sheets - parameters
type of material galvanised, poliester painted steel sheets
steel sheet thickness 0,5 mm
galvanic layer thickness 225 g/m² - 275 g/m²
poliester coating layer 25 μm
decorative varhinsh 2V078
bottom varnish 1G410 - 7 μm
Possible steel thickness 0,45mm - 0,6mm
Protective film

Sandwich panel claddings (prepainted steel sheet covers and flashings) are covered with a layer of protective film. The protective film must be removed from the panels before 1 month after recieving the plates. For longer storage panels should be protected from sun exposure, extremal temperatures and other atmospheric conditions. A good practice is to place panel packs with a small decrease, causing rainwater run off.
Cutting of sandwich panels and flashings.

You should use proper tools for cutting sandwich panels, that do not overheat the steel surface. Excessive heat during metal cutting (eg. An angle grinder with discs) damages the galvanic coating of steel sheets and can be a cause of corrosion. Great heat can also excessively damage the core, insulation. To cut sandwich panels use circular saws for metal cutting, special sandwich panel - saws or other proper equipment. When cutting panels remove excess metal filings that can cause corrosion, and prevent sparks and filings from falling onto other panels.
Standard ABO colors

RAL 9010

RAL 9002

RAL 9006

RAL 3011

RAL 8017

RAL 7024

The colors depicted on the website are for guidance only and can be different from real color coatings on panels.
Availability, production possibilities and pricing of certain colors are determined individually.
Other color examples

RAL 1002

RAL 1015

RAL 1021

RAL 5010

RAL 6029

RAL 7035

RAL 9007

The colors depicted on the website are for guidance only and can be different from real color coatings on panels.
Availability, production possibilities and pricing of certain colors are determined individually.
Dark colors, panel lengths - warning

We do not recommend the use of dark colors (for example, according to RAL palette: 3011, 3005, 8017, 7024, 6005) due to sunlight absorption and overheating of steel sheets on panels. Temperature expansion of metal and possible damages caused by overheating and temperature changes may result in deterioration of aesthetic or damage of panels. We do not take responsibility for damages resulting from the use of very dark panels or too long elements. We do not provide guarantee for panels ordered against our recommendations concerning colors and lengths.
Color Repeatability

We do not guarantee exactly the same color tone of the painted surfaces for orders placed in different terms. This concerns especially metallic colors (for example RAL 9006 or RAL 9007).

Snow and wind load tables

Table of allowed snow loads for EURO-therm D-St roof sandwich panels with EPS core
on single and multispan roofs daN/m2
core, insulation thickness (mm) Maximum panel span (m), depending on the load
70/100* daN/m2 90/130* daN/m2 110/155* daN/m2
70 3,3 3,0 2,7
125 3,6 3,3 3,0
150 3,9 3,6 3,3
170 4,2 3,9 3,6
190 4,5 4,2 3,9
Force per one screw (with metal washer/underlay) should not exceed 150daN.
* characteristic load / calculative load
Table of allowed wind loads for EURO-therm S-St single- and multispan
wall sandwich panels with EPS core.
allowed wind load, with inside temperature +20°C (daN/m2).
core thickness (mm) 70 100 125 150 170 200 230
span distance (m) 2,4 91 - - - - - -
2,7 74 125 - - - - -
3 60 105 145 - - - -
3,3 49 89 124 - - - -
3,6 - 75 107 139 - - -
3,9 - 65 93 121 145 - -
4,2 - - 81 107 128 - -
4,5 - - 70 94 113 144 -
4,8 - - 61 83 101 129 -
5,1 - - - 74 90 116 143
5,4 - - - 65 80 104 128
5,7 - - - - 72 94 117
6 - - - - 65 85 106
6,3 - - - - - 77 96
6,6 - - - - - 68 88
Force per one screw (with steel washer) should not exceed 100daN.
Table of allowed wind loads for EURO-therm S-St single- and multispan
wall sandwich panels with EPS core.
allowed wind load, with inside temperature +0°C (daN/m2)
core thickness (mm) 150 170 200 230
span distance (m) 2,4 - - - -
2,7 - - - -
3 151 - - -
3,3 131 - - -
3,6 114 156 - -
3,9 100 137 - -
4,2 88 121 153 -
4,5 80 106 136 -
4,8 - 95 122 149
5,1 - 85 108 134
5,4 - - 97 120
5,7 - - - 100
Force per one screw (with metal washer/underlay) should not exceed 100daN.
The informations and materials given above

(on this website)

are for informational purposes only. Informations contained therein are not legally binding and do not constitute an offer within the meaning of Article 66 § 1 of the polish civil code do not constitute assurance, in particular within the meaning of art. 556 of the polish civil code. Description and confirmation of availability of goods takes place only during sale according to specifications provided by the Sandwich Panel Factory ABO (Fabryka Płyt Warstwowych ABO Boguslaw Bugała) in the form of a contract, purchase order or order confirmation.
back print
address:
Fabryka Płyt Warstwowych ABO Bogusław Bugała
factory: Mchowo 100, 06-300 Przasnysz
invoicing: Mchowo 1, 06-300 Przasnysz
województwo mazowieckie, POLAND
GPS: N 53°04'15.09" | E 20°51'02.88"
contact:
tel: (+48) 29-751-34-01
fax: (+48) 29-751-34-03
e-mail:
Bank: Bank Pekao S.A. / Bank account No.:
EURO: (IBAN): PL59 1240 1617 1978 0010 3691 5883
PLN: (IBAN): PL39 1240 1617 1111 0010 3691 5652
SWIFT: PKOPPLPW

Last update:  13.10.2017 - Copyright © 2016 Fabryka Płyt Warstwowych ABO
webmaster 

Powered by PHP Poprawny HTML 4.01 Transitional Poprawny CSS